-------------- Legal Notices -------------- ©2018 Siemens Product Lifecycle Management Software Inc. All Rights Reserved Software, file formats, and audiovisual displays may be used pursuant to the applicable Software License Agreement and contain confidential and proprietary information of Siemens Product Lifecycle Management Software Inc.; which is protected by copyright and trade secret law. Such materials may not be reproduced or transferred to other documents or used or disclosed to others for manufacturing or for any other purpose except as specifically authorized within the terms of the Software License Agreement, or as specifically authorized in writing by Siemens Product Lifecycle Management Software Inc. Siemens Product Lifecycle Management Software Inc. 5800 Granite Parkway Suite 600 Plano, TX. 75024 -------------------- End of Legal Notices -------------------- -------------- Release Notes: -------------- Microsoft Installer (MSI) Maintenance Pack Solid Edge 2019 (V219) Version: 219.00.02.05 Solid Edge 2019 Maintenance Packs will be available to address CRITICAL items thru the year following the release. The release date for Solid Edge 2019 was 06/25/2018. Therefore, the Solid Edge 2019 Maintenance Pack cutoff date is 12/31/2019. Microsoft Windows 10 releases Feature Updates every six months. Microsoft does not use Windows 10 Feature Updates as an avenue to deliver security-related patches. All quality-related patches, including security and reliability hot-fixes, will continue to be delivered outside of this Feature Update process. Therefore, if your production use of Solid Edge was negatively impacted as a result of the last Microsoft Windows 10 Feature Update, you should consider configuring your Windows 10 machines to delay the deployment of Windows 10 Feature Updates. Configuring your Windows 10 machines by moving the machines into the "Semi-Annual Channel" servicing channel will delay the installation of Feature Updates for approximately four months following the initial release. During this time, you and your IT organization will have the opportunity to review the suitably of the Feature Update, including determining any negative impact, upon the applications that you use in your production environment, such as Solid Edge. This four-month window of time between Microsoft initially releasing the Feature Update to targeted machines and releasing the Feature Update for general deployment to the enterprise will also provide our development team time to review and react to changes introduced by Windows 10 Feature Updates, thereby helping keep you as productive as possible.  When you download an MP for a Solid Edge Portfolio product such as Technical Publications, Modular Plant Design, Electrical, and so on, you should also install the related base Solid Edge MP. At times a change is required in both the base product and portfolio product to address a software issue. -------------------- End of Release Notes -------------------- ------------------- Installation Notes: ------------------- • MSI Product Updates can be applied on top of the base release and or existing Product Update with a lesser version. • MSI Product Updates are all inclusive, i.e. fixes delivered in MP3 include all fixes delivered in MP1 and MP2. • MSI Product Updates calculate free disk space before installing. Please note that there have been cases where the Disk Space Computation takes several minutes to complete. Please be patient. • MSI Product Updates can be uninstalled without having to remove the base Solid Edge product. • Uninstalling a MSI Product Update will restore the installation to the state before the Product Update was applied. • PLEASE NOTE: When uninstalling a MSI Product Update, the original source media and the previous Product Update package, if any, must be available to allow the recovery of previous file versions. • The current MSI Product Update will be the only Update listed and available for uninstallation. After the current Update is uninstalled, the previous Update will become the current Update, if there were multiple Updates installed. • MSI Product Updates are uninstalled via the Control Panel (Uninstall a program –> View installed updates -> Uninstall). Silent MSI MP Install: Solid_Edge_MSI_MP1.exe /s /v"/qn /L*v %TEMP%\mysilentupdate.log" “/s” is an InstallShield switch that makes the InstallShield EXE run silent. “/v” is an InstallShield switch that passes the string following it in quotes to the wrapped MSI “/qn” The “q” sets the UI level of the MSI and the “n” is it’s option for “No UI” Be careful attempting to output a log file as MSI will not create directories if they don’t exist. So, if you want to create a log file set your path to a directory that exits or to “%TEMP%\mysilentupdate.log” as “%TEMP%” is an environment variable which translates into “c:\users\yourusername\local\appdata\temp”. ------------------- End of Installation ------------------- ---------------------------------------------- PRs Resolved in Solid Edge 2019 MP2 (v219 MP2) ---------------------------------------------- ===General=== PR 9219060: License borrowing fails ===Assembly=== PR 8358637: Assembly relationships get failed in case of replacing frame section PR 9070763: failing assembly center-plane relationships PR 9122932: associative included 2d edges from embedded weldments are not binding PR 9043888: Additional changes to help reduce accidental component placement from Pathfinder PR 9149569: Incorrect occurrence node used for calculation PR 9255548: Support Harness topology exchange with SE Electrical PR 9261820: User is not able to exchange harness data using connected mode PR 8390834: capture fit from old asm causes issues PR 9260675: Assembly relationship names are incorrect when the locale uses a comma decimal symbol PR 9254326: Not possible to delete all results for one mode in one operation PR 9235043: SE crashes when closing assembly after replacing parts in the assembly with a new part ===Draft=== PR 9205237: Tolerance Table does not show shaft value when type Fit Hole/Shaft is used. PR 9212300: Block Library Draft File is Opening Inactive and cannot edit block PR 9214776: Views not allowing reorientation PR 9227323: Problem with expanded Character spacing, when printing or saving as PDF ===Part/Sheet Metal=== PR 9199752: Seeing a strange problem with a cutout disappearing on a rolled Sheet metal part PR 9223490: Saved settings for hole doesn't work for Pitch, a regression against ST10 PR 9232884: Accelerated Sketch Display causes the sketch to Move PR 9157575: Sheet metal Part Will Not Flatten PR 9249047: Unable to flatten a part that got rebent after an unbend to add new features PR 9253720: Thread representation is missing PR 9210400: Mirroring Synchronous Sheet Metal w/ circular cutout 2 Bend corners PR 9163871: After editing and updating a gear, Pattern features are removed in History ===Translators=== PR 8387280: Error during Solid Works data migration - "migration terminated" PR 8329150: DXFin: Dimension lines are not trimmed ===Illustrations & 3D Publisher === PR 9105399: Tech Pub 2019 MP1 installer system icon tip says "ST10" ===Design Manager=== PR 8382986: Slow performance with Solid Edge DM Search ===Data Management=== PR 9145113: Unable to set Custom Properties when ProSeed file is on network drive PR 9050905: Drawing of part revised from assembly is not being set to available PR 9223036: custom properties changing when revising and revised or save as draft released ===Solid Edge Requirements=== PR 9249388: Recognize the Project ID in Polarion URL PR 9249395: Opening a Work Item from the docking pane does not set the project in Polarion PR 9249402: Error when publishing to a work item that has an existing attachment ===Insight=== PR 9206378: Particular workflow is prompting user to check in edited files instead of Upload ===Teamcenter Integration for Solid Edge=== PR 8388364: SEEC API: SetPDMProperties doesn't support Name Prefix Item / ItemRevision PR 9173683: SEEC Admin: Updated SEEC Feature Packages PR 9201997: Issues with Solid Edge Data Preparation Utility PR 9174734: SEEC / Active Workspace error at login: Unable to get property uid PR 9191395: mapped properties /master=cad will modify SE property when cleared in RAC PR 9127806: Honor new preference to clear properties --- End ---