-------------- Legal Notices -------------- ©2019 Siemens Product Lifecycle Management Software Inc. All Rights Reserved Software, file formats, and audiovisual displays may be used pursuant to the applicable Software License Agreement and contain confidential and proprietary information of Siemens Product Lifecycle Management Software Inc.; which is protected by copyright and trade secret law. Such materials may not be reproduced or transferred to other documents or used or disclosed to others for manufacturing or for any other purpose except as specifically authorized within the terms of the Software License Agreement, or as specifically authorized in writing by Siemens Product Lifecycle Management Software Inc. Siemens Product Lifecycle Management Software Inc. 5800 Granite Parkway Suite 600 Plano, TX. 75024 -------------------- End of Legal Notices -------------------- -------------- Release Notes: -------------- Microsoft Installer (MSI) Maintenance Pack Solid Edge 2019 (V219) Version: 219.00.07.04 Solid Edge 2019 Maintenance Packs will be available to address CRITICAL items thru the year following the release. The release date for Solid Edge 2019 was 06/25/2018. Therefore, the Solid Edge 2019 Maintenance Pack cutoff date is 12/31/2019. Teamcenter Integration for Solid Edge (SEEC) - If you have installed the Solid Edge 2019 SEEC Admin from the Full Product download area, Teamcenter_Integration_for_SE_Admin_2019.zip, please install the updated SEEC Admin product, SEECAdministratorV219_MP1.zip from the Solid Edge Product Update area to ensure you have the changes made to support MP1. Beyond the MP1 install, no further SEEC Admin updates are required with this MP release. Solid Edge Portfolio Products - When you download an MP for a Solid Edge Portfolio product such as Technical Publications, Modular Plant Design, Electrical, and so on, you should also install the related base Solid Edge MP. At times a change is required in both the base product and portfolio product to address a software issue. Microsoft Windows 10 releases Feature Updates every six months. Microsoft does not use Windows 10 Feature Updates as an avenue to deliver security-related patches. All quality-related patches, including security and reliability hot-fixes, will continue to be delivered outside of this Feature Update process. Therefore, if your production use of Solid Edge was negatively impacted as a result of the last Microsoft Windows 10 Feature Update, you should consider configuring your Windows 10 machines to delay the deployment of Windows 10 Feature Updates. Configuring your Windows 10 machines by moving the machines into the "Semi-Annual Channel" servicing channel will delay the installation of Feature Updates for approximately four months following the initial release. During this time, you and your IT organization will have the opportunity to review the suitably of the Feature Update, including determining any negative impact, upon the applications that you use in your production environment, such as Solid Edge. This four-month window of time between Microsoft initially releasing the Feature Update to targeted machines and releasing the Feature Update for general deployment to the enterprise will also provide our development team time to review and react to changes introduced by Windows 10 Feature Updates, thereby helping keep you as productive as possible.  -------------------- End of Release Notes -------------------- ------------------- Installation Notes: ------------------- • MSI Product Updates can be applied on top of the base release and or existing Product Update with a lesser version. • MSI Product Updates are all inclusive, i.e. fixes delivered in MP3 include all fixes delivered in MP1 and MP2. • MSI Product Updates calculate free disk space before installing. Please note that there have been cases where the Disk Space Computation takes several minutes to complete. Please be patient. • MSI Product Updates can be uninstalled without having to remove the base Solid Edge product. • Uninstalling a MSI Product Update will restore the installation to the state before the Product Update was applied. • PLEASE NOTE: When uninstalling a MSI Product Update, the original source media and the previous Product Update package, if any, must be available to allow the recovery of previous file versions. • The current MSI Product Update will be the only Update listed and available for uninstallation. After the current Update is uninstalled, the previous Update will become the current Update, if there were multiple Updates installed. • MSI Product Updates are uninstalled via the Control Panel (Uninstall a program –> View installed updates -> Uninstall). Silent MSI MP Install: Solid_Edge_MSI_MP1.exe /s /v"/qn /L*v %TEMP%\mysilentupdate.log" “/s” is an InstallShield switch that makes the InstallShield EXE run silent. “/v” is an InstallShield switch that passes the string following it in quotes to the wrapped MSI “/qn” The “q” sets the UI level of the MSI and the “n” is it’s option for “No UI” Be careful attempting to output a log file as MSI will not create directories if they don’t exist. So, if you want to create a log file set your path to a directory that exits or to “%TEMP%\mysilentupdate.log” as “%TEMP%” is an environment variable which translates into “c:\users\yourusername\local\appdata\temp”. ------------------- End of Installation ------------------- ---------------------------------------------- PRs Resolved in Solid Edge 2019 MP7 (v219 MP7) ---------------------------------------------- ===Assembly=== PR 9321519: Assembly components not visible on the screen or in pathfinder PR 9380800: Wire Harness license is being checked out even though user is not in it PR 9385677: Unable to recognize pattern features on a part file with a part copy feature PR 9390112: Part file will be deleted, if an assembly will not be saved PR 9421254: Solid Edge rashes when trying save the assembly each time (Has wire-harness) PR 9203749 frames about "Extend/Trim a frame segment causes unexpected results." PR 9428554: Changes to help address random crashes PR 9444743: Fixed a reproducible crash captured in a submitted crashlog PR 9233005: When IPA the locating of geometry outside of the IPA path was incorrect PR 8407232 Parts cannot be deleted, if all parts are activated PR 9242392: Solid Edge crashes while importing harness data using a specific workflow ===Draft=== PR 9284474 : Problem with Horizontal Break line for Broken View ===Part/Sheet Metal=== PR 9409771: Solid Edge aborts when adding and editing custom material property PR 9436802: The costumer made one .par via mirror component and cannot change the material PR 9273919: Cannot edit the property Comments of Solid Edge documents in Windows Explorer PR 8359548 : Radial dimensions are not converted to driving (blue) with create 3D command PR 8405442: Performance issue when material file is on a share PR 9385673: When starting Solid Edge, it also tries to start Microsoft Excel, which crashes PR 9402907: Stamp in Design for Cost does not recognize patterned occurrences PR 9330034: Locate issues with small parts PR 9433809: Text profile displays additional geometry with accelerated sketch PR 9226405: Patterned helical cutout does not maintain correct distance between occurrences PR 9382697: Reference plane is not staying in correct position ===Translators=== PR 9143216: STEP file does not open correct, models missing PR 8938269: SW2013 After the data is migrated, the configuration has no conversion PR 9350279: When trying to bring NX file into SE, SE aborts PR 9363120: Object Border set not shown is shown in DXF result PR 9474274: SW2014 - Migrated drawings are not the same PR 8989682: Open the step file in SE, the result is wrong and not complete ===Data Management=== PR 9419705 : Impossible to replace parts located in a Solid Edge Data Management Standard Parts Folder ===Teamcenter Integration for Solid Edge=== PR 9342842: Solid Edge crashes when editing a part PR 9397514: Performance suffers on Teamcenter Tab PR 9427010: Replace a new revision with an older revision PR 9428205: Solid Edge crashed while doing Multi - body Publish --- End ---