-------------- Legal Notices -------------- ©2019 Siemens Product Lifecycle Management Software Inc. All Rights Reserved Software, file formats, and audiovisual displays may be used pursuant to the applicable Software License Agreement and contain confidential and proprietary information of Siemens Product Lifecycle Management Software Inc.; which is protected by copyright and trade secret law. Such materials may not be reproduced or transferred to other documents or used or disclosed to others for manufacturing or for any other purpose except as specifically authorized within the terms of the Software License Agreement, or as specifically authorized in writing by Siemens Product Lifecycle Management Software Inc. Siemens Product Lifecycle Management Software Inc. 5800 Granite Parkway Suite 600 Plano, TX. 75024 -------------------- End of Legal Notices -------------------- -------------- Release Notes: -------------- Microsoft Installer (MSI) Maintenance Pack Solid Edge 2019 (V219) Version: 219.00.08.04 Solid Edge 2019 Maintenance Packs will be available to address CRITICAL items thru the year following the release. The release date for Solid Edge 2019 was 06/25/2018. Therefore, the Solid Edge 2019 Maintenance Pack cutoff date is 12/31/2019. Teamcenter Integration for Solid Edge (SEEC) - If you have installed the Solid Edge 2019 SEEC Admin from the Full Product download area, Teamcenter_Integration_for_SE_Admin_2019.zip, please install the updated SEEC Admin product, SEECAdministratorV219_MP1.zip from the Solid Edge Product Update area to ensure you have the changes made to support MP1. Beyond the MP1 install, no further SEEC Admin updates are required with this MP release. Solid Edge Portfolio Products - When you download an MP for a Solid Edge Portfolio product such as Technical Publications, Modular Plant Design, Electrical, and so on, you should also install the related base Solid Edge MP. At times a change is required in both the base product and portfolio product to address a software issue. Microsoft Windows 10 releases Feature Updates every six months. Microsoft does not use Windows 10 Feature Updates as an avenue to deliver security-related patches. All quality-related patches, including security and reliability hot-fixes, will continue to be delivered outside of this Feature Update process. Therefore, if your production use of Solid Edge was negatively impacted as a result of the last Microsoft Windows 10 Feature Update, you should consider configuring your Windows 10 machines to delay the deployment of Windows 10 Feature Updates. Configuring your Windows 10 machines by moving the machines into the "Semi-Annual Channel" servicing channel will delay the installation of Feature Updates for approximately four months following the initial release. During this time, you and your IT organization will have the opportunity to review the suitably of the Feature Update, including determining any negative impact, upon the applications that you use in your production environment, such as Solid Edge. This four-month window of time between Microsoft initially releasing the Feature Update to targeted machines and releasing the Feature Update for general deployment to the enterprise will also provide our development team time to review and react to changes introduced by Windows 10 Feature Updates, thereby helping keep you as productive as possible.  -------------------- End of Release Notes -------------------- ------------------- Installation Notes: ------------------- • MSI Product Updates can be applied on top of the base release and or existing Product Update with a lesser version. • MSI Product Updates are all inclusive, i.e. fixes delivered in MP3 include all fixes delivered in MP1 and MP2. • MSI Product Updates calculate free disk space before installing. Please note that there have been cases where the Disk Space Computation takes several minutes to complete. Please be patient. • MSI Product Updates can be uninstalled without having to remove the base Solid Edge product. • Uninstalling a MSI Product Update will restore the installation to the state before the Product Update was applied. • PLEASE NOTE: When uninstalling a MSI Product Update, the original source media and the previous Product Update package, if any, must be available to allow the recovery of previous file versions. • The current MSI Product Update will be the only Update listed and available for uninstallation. After the current Update is uninstalled, the previous Update will become the current Update, if there were multiple Updates installed. • MSI Product Updates are uninstalled via the Control Panel (Uninstall a program –> View installed updates -> Uninstall). Silent MSI MP Install: Solid_Edge_MSI_MP1.exe /s /v"/qn /L*v %TEMP%\mysilentupdate.log" “/s” is an InstallShield switch that makes the InstallShield EXE run silent. “/v” is an InstallShield switch that passes the string following it in quotes to the wrapped MSI “/qn” The “q” sets the UI level of the MSI and the “n” is it’s option for “No UI” Be careful attempting to output a log file as MSI will not create directories if they don’t exist. So, if you want to create a log file set your path to a directory that exits or to “%TEMP%\mysilentupdate.log” as “%TEMP%” is an environment variable which translates into “c:\users\yourusername\local\appdata\temp”. ------------------- End of Installation ------------------- ---------------------------------------------- PRs Resolved in Solid Edge 2019 MP7 (v219 MP7) ---------------------------------------------- ===General=== PR 8560446: ALT key causes "Attach Locale resources" Error in Korean UI (PR9283547) PR 9492059: Open 3d models with read-only access when running Solid Edge in viewer mode ===Assembly=== PR 9183972: Solid Edge crashes when opening a .jt PR 9347654: Added safety checks for some assembly crashlog aborts PR 9386843: Deleting parts causes wire path to be deleted, which leads to an abort PR 9465131: Scroll wheel zoom in/out view manipulation is really slow PR 9466670: Can't update model to Keyshot in SE2019 MP6 PR 9498580: Manual draw command of explode lines not working correctly PR 9502953: Solid Edge crashing when opening wire harness assembly ===Draft=== PR 9446381: When the drawing is inactivated and opened, the balloons become "NA" PR 9494273: Leader annotation behave not correctly by moving leader line ===Part/Profile/Sheet Metal=== PR 9313757: Standard Parts Part finder Error Unit bar 100 Faktor to high as original value PR 9383904: issue using include and colinear to drive a normal cutout PR 9455273: 'Save As' followed by an additional 'Save' leads into an abort PR 9497664: Profile Error Assistant not displaying PR 8411799: Unable to extend V13.00 category with new master parts ===Translators=== PR 9366800: SW Data Migration: Missing File Error PR 9243839: Solid Edge crashes when opening a specific NX file PR 9325596: Dimension scales are incorrect when multiple DV scales are exported PR 9328958: Opening DXF files is very slow ===Design Manager=== PR 8417497: Design Manager missing Property Manager in non-Insight mode PR 9498880: Preview pane causes errors with scrolling and open files that are in insight ===Data Management=== PR 9497402: SE PDM problem after MP7 installation ===Teamcenter Integration for Solid Edge=== PR 9397674: Standard Parts Item name is filled with Item ID instead of configured Project Name PR 9429418: Error message when open read only SE files from Teamcenter PR 9432227: Assembly files marked dirty after updating to SE 2019 PR 9472063: Inconsistent behavior driven reference during delete workflow PR 9472132: ATTI crashing while import data in manage mode PR 8417685: Bom line not found error during upload PR 9486286: Download to cache will change BOM synchronization option PR 9498560: SEEC_Synchronize_ItemNumbers does not work with Method=3 and Driven References PR 9352385: Construction Components not synced to TC for an AP asm PR 9432015: When DFT of ASM has indep - view of child PAR, SESE refreshes L - Panel incorrec PR 9433947: Revise/SaveAs on SESE fails when TC side BVR of Sub-Asm is updated after upload. PR 9435448: On SESE, BOM of the R-Panel is overridden when Where Used after Set Action PR 9487158: Very low open performance of complex draft. PR 9507197: Adjustable assembly recognition trouble using SEEC API CreateBOMandRelations PR 9505900: SEEC not listed when trying to borrow licenses --- End ---